3 resultados para zero

em Archivo Digital para la Docencia y la Investigación - Repositorio Institucional de la Universidad del País Vasco


Relevância:

20.00% 20.00%

Publicador:

Resumo:

23 p. -- An extended abstract of this work appears in the proceedings of the 2012 ACM/IEEE Symposium on Logic in Computer Science

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spurious oscillations are one of the principal issues faced by microwave and RF circuit designers. The rigorous detection of instabilities or the characterization of measured spurious oscillations is still an ongoing challenge. This project aims to create a new stability analysis CAD program that tackles this chal- lenge. Multiple Input Multiple Output (MIMO) pole-zero identification analysis is introduced on the program as a way to create new methods to automate the stability analysis process and to help designers comprehend the obtained results and prevent incorrect interpretations. The MIMO nature of the analysis contributes to eliminate possible controllability and observability losses and helps differentiate mathematical and physical quasi-cancellations, products of overmodeling. The created program reads Single Input Single Output (SISO) or MIMO frequency response data, and determines the corresponding continuous transfer functions with Vector Fitting. Once the transfer function is calculated, the corresponding pole/zero diagram is mapped enabling the designers to analyze the stability of an amplifier. Three data processing methods are introduced, two of which consist of pole/zero elimina- tions and the latter one on determining the critical nodes of an amplifier. The first pole/zero elimination method is based on eliminating non resonant poles, whilst the second method eliminates the poles with small residue by assuming that their effect on the dynamics of a system is small or non-existent. The critical node detection is also based on the residues; the node at which the effect of a pole on the dynamics is highest is defined as the critical node. In order to evaluate and check the efficiency of the created program, it is compared via examples with another existing commercial stability analysis tool (STAN tool). In this report, the newly created tool is proved to be as rigorous as STAN for detecting instabilities. Additionally, it is determined that the MIMO analysis is a very profitable addition to stability analysis, since it helps to eliminate possible problems of loss of controllability, observability and overmodeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fe3O4 and ZnxFe3-xO4 pure and doped magnetite magnetic nanoparticles (NPs) were prepared in aqueous solution (Series A) or in a water-ethyl alcohol mixture (Series B) by the co-precipitation method. Only one ferromagnetic resonance line was observed in all cases under consideration indicating that the materials are magnetically uniform. The shortfall in the resonance fields from 3.27 kOe (for the frequency of 9.5 GHz) expected for spheres can be understood taking into account the dipolar forces, magnetoelasticity, or magnetocrystalline anisotropy. All samples show non-zero low field absorption. For Series A samples the grain size decreases with an increase of the Zn content. In this case zero field absorption does not correlate with the changes of the grain size. For Series B samples the grain size and zero field absorption behavior correlate with each other. The highest zero-field absorption corresponded to 0.2 zinc concentration in both A and B series. High zero-field absorption of Fe3O4 ferrite magnetic NPs can be interesting for biomedical applications.